Projects
: RCA Turbine Failure PowerGen W501D4


- Provided
on-site supervision of disassembly
- Selected
components for laboratory analysis
- Supervised
metallurgical laboratory analysis (macros, micros, SEM, EDS)
- Overheating
and melting of stage 1, 2, & 3 vanes
- HCF
failure of stage 3 rotating blades (1st mode)

- Liquid carry-over
found in natural gas fuel
- Machine had tripped
due to high blade path temp spread and high exhaust temp
- Performed harmonic
content analysis
- Result: missing
stage 2 vane airfoils caused forced vibration of stage 3 blades near
5th harmonic of running speed; blade fundamental frequency is slightly
above 5th harmonic
|
|